Independently lab tested: no harmful heavy metals or bacteria added to your water.
We want you to know exactly what goes into your glass. That is why the TapSmart™ tap water filter was sent for independent hygiene safety testing at CAS Testing Technical Services (Guangzhou) Co., Ltd.
What is a soak test?
In a hygiene safety soak test, water is left standing inside the filter and then analysed. It is compared with a “blank” sample of the same water that never touched the filter. This shows whether the filter’s own materials release anything into the water. Two complete units were tested.
The results
No lead, cadmium, mercury, hexavalent chromium, arsenic, volatile phenols or bacteria were detected in water that had been standing in the filter. Colour, cloudiness, taste, odour and visible particles were unchanged. Every result passed the required safety standard.
| Parameter | Unit | Blank (no filter) | Filter sample 1 | Filter sample 2 | Safety requirement | Added by filter | Result |
|---|---|---|---|---|---|---|---|
| Colour | degrees | <5 | <5 | <5 | Increase ≤5 | None | Pass |
| Turbidity (cloudiness) | NTU | <0.5 | <0.5 | <0.5 | Increase ≤0.5 | None | Pass |
| Odour & taste | – | None | None | None | No abnormal odour or taste | None | Pass |
| Visible particles | – | None | None | None | No visible fragments or debris | None | Pass |
| Lead | mg/L | <0.00007 | <0.00007 | <0.00007 | Increase ≤0.001 | None detected | Pass |
| Cadmium | mg/L | <0.00006 | <0.00006 | <0.00006 | Increase ≤0.0005 | None detected | Pass |
| Mercury | mg/L | <0.00007 | <0.00007 | <0.00007 | Increase ≤0.0002 | None detected | Pass |
| Chromium (hexavalent) | mg/L | <0.004 | <0.004 | <0.004 | Increase ≤0.005 | None detected | Pass |
| Arsenic | mg/L | <0.00009 | <0.00009 | <0.00009 | Increase ≤0.001 | None detected | Pass |
| Volatile phenols | mg/L | <0.0020 | <0.0020 | <0.0020 | Increase ≤0.002 | None detected | Pass |
| Total bacterial count | CFU/mL | Not detected | Not detected | Not detected | ≤100 | None detected | Pass |
| Total coliforms | MPN/100mL | Not detected | Not detected | Not detected | None per 100 mL | None detected | Pass |
| Thermotolerant (faecal) coliforms | MPN/100mL | Not detected | Not detected | Not detected | None per 100 mL | None detected | Pass |
| Organic matter (permanganate index, as O2) | mg/L | 0.24 | 0.68 | 0.64 | Increase ≤2 | Small rise (+0.40 to +0.44), well within limit | Pass |
“<” means below the laboratory’s detection limit. “None detected” means no difference was found between the blank and the filtered samples.
About this test
- Laboratory: CAS Testing Technical Services (Guangzhou) Co., Ltd.
- Report number: JKS24060003(R), Table 1 – Hygiene safety test results
- Samples: two complete filter units
- Translation: this is an English translation of the soak test section of the original Chinese report, prepared by Sustainabuy. The original report is available on request.
Shop the TapSmart™ Tap Water Filter Kit · See all water filters